Preaload Image
ruby-nc
For unbeatable crossability & deliverability

Features

  • Tailor-made polymer with sleek finish to refrain collision with stent struts.
  • Direct torque transmission design allows superior steerability and cantrol.
  • Pushability, trackability and excellent progressive flexibility of the distal area.
  • Ultra-smooth transition area and lubricious hydrophilic coating for friction free performance.
  • Ergonomic, transparant hub facilitates safe conection.
  • Proximal marker bands at 90 and 100 CM
  • Strong, durable and flexible proprietary balloon material provides high-pressure capability and a low growth profile.
  • The extremely flexible tip helps the balloon catheter to reach tortuous anatomies
  • Durable compliant balloon designed to tackle multiple dilatation needs
  • Compliant balloon material designed to smooth entiregraft
ruby-1

Pushability

  • A parallel guide wire exit port gurantees best pushability and a better dye flow injection.
  • Lower profile, new jacketed hypo tube design and a exclusive blend of distal shaft materials for more responsive push and track.
ruby-nc-g1

Trackability

  • Excellent, responsive trackability by virtue of its design.
  • Highly flexible catheter outer body maximizes trackability performance.
ruby-nc-g2
ruby-nc-g3
  • Integrated markers and small shaft diameter facilitates contrast media injection in small size guiding catheters.
  • Rapid inflation/deflation and excellant rewrap characteristics.
  • Reduced balloon profile
ruby-nc-g4
  • Focused inflation force.
  • Controlled pushing of stent towords the vessel wall
  • Incomplete apposition may contribute to thrombosis formation and SAT
  • Stent under-expansion may increase risk for restenosis
  • POst-dilatation reduces target vessel revascularization (TVR)
  • Uniform stent apposition facilitates uniform drug absorption into endothelial tissue
ruby-nc-g5

Common Technical Specifications

Design Rapid Exchange
Balloon compliance Non-compliant
Distal Shaft (outer diameter) 0.89 mm
Proximal Shaft (outer diameter) 0.76 mm
Usable catheter length 1409-1419 mm
Lowest Crossing Profile 0.8 mm
Minimum guide catheter compatible 0.058” /5 Fr
Guide wire compatible 0.014″
Nominal inflation pressure 10 ATM
Rated Burst Pressure 18 ATM
Marker bands Two platinum iridium markers
Tip profile 0.018″
ATM Ballon Diameter Versus Inflation Pressure
2.50 2.75 3.00 3.50 4.00
6 2.41 2.68 2.93 3.41 3.90
8 2.45 2.70 2.96 3.45 3.95
10 2.50 2.75 3.00 3.50 4.00
12 2.54 2.79 3.05 3.55 4.05
14 2.57 2.83 3.10 3.60 4.11
16 2.61 2.87 3.15 3.65 4.16
18 2.65 2.92 3.20 3.69 4.20
20 2.68 2.97 3.25 3.73 4.25
22 2.72 3.01 3.29 3.78 4.29
Nominal Pressure Rated Burst Pressure (RBP)

Product Ordering Information

Length 2.50 mm (Dia) 2.75 mm (Dia) 3.00 mm (Dia) 3.50 mm (Dia) 4.00 mm (Dia)
8 mm RNC2500-08 RNC2750-08 RNC3000-08 RNC3500-08 RNC4000-08
10 mm RNC2500-10 RNC2750-10 RNC3000-10 RNC3500-10 RNC4000-10
12 mm RNC2500-12 RNC2750-12 RNC3000-12 RNC3500-12 RNC4000-12
13 mm RNC2500-13 RNC2750-13 RNC3000-13 RNC3500-13 RNC4000-13
15 mm RNC2500-15 RNC2750-15 RNC3000-15 RNC3500-15 RNC4000-15
18 mm RNC2500-18 RNC2750-18 RNC3000-18 RNC3500-18 RNC4000-18
20 mm RNC2500-20 RNC2750-20 RNC3000-20 RNC3500-20 RNC4000-20

Order Now